Orijinal gönderinin sahibi: Abrsvc ,

Metin:

From what I can see from the service manual, a good cleaning may be all that is needed.  There will need to be some dis-assembly however.  This is not something that should be done for the first time.  The relevant parts are listed below.

A-1861-457-A  RL-128 Board complete (Board on the top of the camera that has the “switch” on it.

4-416-599-01   Plate, rotary    (This is the part that rotates to make contacts.  ie. switch)

I only have a paper copy of the manual with no easy way to upload the relevant pages.  There may be a copy online somewhere though.   Note: There are specific instructions for proper installation/alignment of the switch that must be followed in the manual as well.

Hope this helps.

Dan

Durum:

open