Hi @tommysparks1 ,
What is the model number of the freezer?
-Are there any oily residues on the condenser coils or near the compressor which may indicate a leak of refrigerant?
+Are there any oily residues on the condenser coils or near the compressor which may indicate a leak of refrigerant? Also are the condenser coils clean and free from accumulated dust etc?
Interesting that there is ice on the evap unit at 35F. Ice only forms at 32F. Are the temps shown found using a thermometer or from a display panel if it has one?
Test the door seals by placing a sheet of paper between the door and the door jamb and with the door closed try to pull it out. It will come out with a bit of effort but not that easily and it definitely should not just fall out. Try this at various places around the door, top, bottom and both sides.

Durum:

open

Orijinal gönderinin sahibi: jayeff

Metin:

Hi @tommysparks1 ,

What is the model number of the freezer?

Are there any oily residues on the condenser coils or near the compressor which may indicate a leak of refrigerant?

Interesting that there is ice on the evap unit at 35F. Ice only forms at 32F. Are the temps shown found using a thermometer or from a display panel if it has one?

Test the door seals by placing a sheet of paper between the door and the door jamb and with the door closed try to pull it out. It will come out with a bit of effort but not that easily and it definitely should not just fall out. Try this at various places around the door, top, bottom and both sides.