Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
If the evap unit in the freezer is not icy cold i.e. 0°F, this indicates no or minimal refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
-If there is a problem with the 3 way valve then depending on your location, you ''may'' need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment when working on the sealed system
+If there is a problem with the 3 way valve (unless it is electrical external to the valve) then depending on your location, you ''may'' need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment when working on the sealed system
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
-There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates and controls the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
+There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
If the evap unit in the freezer is not icy cold i.e. 0°F, this indicates no or minimal refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
If there is a problem with the 3 way valve then depending on your location, you ''may'' need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment when working on the sealed system
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates and controls the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
If the evap unit in the freezer is not icy cold i.e. 0°F, this indicates no or minimal refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
-If there is a problem with the 3 way valve then depending on your location, you ''may'' need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment and tools when working on the sealed system
+If there is a problem with the 3 way valve then depending on your location, you ''may'' need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment when working on the sealed system
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates and controls the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
If the evap unit in the freezer is not icy cold i.e. 0°F, this indicates no or minimal refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
-If there is a problem with the 3 way valve then depending on your location, you may need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment and tools when working on the sealed system
+If there is a problem with the 3 way valve then depending on your location, you ''may'' need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment and tools when working on the sealed system
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates and controls the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
If the evap unit in the freezer is not icy cold i.e. 0°F, this indicates no or minimal refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
-If there is a problem with the 3 way valve then depending on your location, you may need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system.
+If there is a problem with the 3 way valve then depending on your location, you may need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system. Besides which you need the appropriate equipment and tools when working on the sealed system
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
-There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that distributes the refrigerant gas between the two evap units depending on temp in each), the temp sensor in the freezer compartment or perhaps the control board.
+There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that regulates and controls the refrigerant gas flow between the two evap units depending on the temp in each compartment), the temp sensor in the freezer compartment or perhaps the control board.
-If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it for whatever reason.
+If the evap unit in the freezer is not icy cold i.e. 0°F, this indicates no or minimal refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
If there is a problem with the 3 way valve then depending on your location, you may need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system.
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
-There are 2 evaporator units in the refrigerator, one in each compartment so it could be a 3 way valve problem (valve that distributes the refrigerant between the two evap units depending on temp) or perhaps the temp sensor in the freezer compartment.
+There are 2 evaporator units in the refrigerator, one in each compartment, refrigerator and freezer, so it could be a 3 way valve problem (valve that distributes the refrigerant gas between the two evap units depending on temp in each), the temp sensor in the freezer compartment or perhaps the control board.
If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
If there is a problem with the 3 way valve then depending on your location, you may need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system.
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment so it could be a 3 way valve problem (valve that distributes the refrigerant between the two evap units depending on temp) or perhaps the temp sensor in the freezer compartment.
If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it for whatever reason.
Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
+If there is a problem with the 3 way valve then depending on your location, you may need to have a licensed repairer fix it. This is due to the environmental regulations regarding the handling of refrigerant gases. The 3 way valve is part of the sealed refrigerant system.
+
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment so it could be a 3 way valve problem (valve that distributes the refrigerant between the two evap units depending on temp) or perhaps the temp sensor in the freezer compartment.
-If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it.
+If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it for whatever reason.
-Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] that may help. It shows how to run the diagnostics. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
+Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] for the model. It shows how to run the diagnostic tests. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
Hopefully this is of some help.

Durum:

open

Düzenleyen: jayeff

Metin:

Hi @rkoster512
There are 2 evaporator units in the refrigerator, one in each compartment so it could be a 3 way valve problem (valve that distributes the refrigerant between the two evap units depending on temp) or perhaps the temp sensor in the freezer compartment.
If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it.
-Here's the [https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] that may help. It shows how to run the diagnostics. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. Note FF = refrigerator, FZ = freezer.
+Here's the [link|https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] that may help. It shows how to run the diagnostics. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. ''Note:'' FF = refrigerator, FZ = freezer.
Hopefully this is of some help.

Durum:

open

Orijinal gönderinin sahibi: jayeff

Metin:

Hi @rkoster512

There are 2 evaporator units in the refrigerator, one in each compartment so it could be a 3 way valve problem (valve that distributes the refrigerant between the two evap units depending on temp) or perhaps the temp sensor in the freezer compartment.

If the evap unit in the freezer is not icy cold this indicates no refrigerant is flowing though it.

Here's the [https://f01.justanswer.com/smitty1486/aeb3a3e0-6390-47be-bc54-482e920626b7_GFE27GMDDES_Tech_Sheet.pdf|mini manual] that may help. It shows how to run the diagnostics. Test # 00 96 checks the FZ (freezer) cooling i.e. the 3 way valve. There is also the FZ thermistor test (#00 27) which checks the freezer temp sensor. Note FF = refrigerator, FZ = freezer.

Hopefully this is of some help.