Ana içeriğe geç

Late 2011 model, A1278 / 2.4 GHz i5 or 2.8 GHz i7 processor.

591 Soru Tümünü görüntüle

Failure to boot after re-applying thermal paste

Block Image

Hello,

my late 2011 MacBook Pro won’t boot. Shortly after displaying the Apple logo, it has the grey/black spiral and approximately at 70 % it’s going on forever. This problem appeared after I took apart the Macbook to apply thermal paste using this guide:

MacBook Pro (13 Zoll, Ende 2011, Unibody) Kühlkörper austauschen

The Safe Mode is working slowly and so far there is no sound. What can I do or have somebody an Idea or solution?

thanks in advance!

Bu soruyu yanıtla Ben de bu sorunu yaşıyorum

Bu iyi bir soru mu?

Puan 0

1 Yorum:

This sounds like too much thermal paste!

Go back in and take the heat sink off, take some picks so we can see things both the chips and the heatsink side and post them here for us to see Adding images to an existing question

tarafından

Yorum Ekle

2 Cevap

Filtre ölçütü:

Try resetting NVRAM/PRAM. First, turn off your Mac then follow these steps:

  1. Press the power button.
  2. Immediately press the Command+Option+P+R keys.
  3. Hold the keys until your Mac restarts and you hear the startup sound, keep holding till you hear the startup sound a second time.
  4. Release the keys.

You could also try an SMC reset:

If the battery is removable:

  1. Turn off your Mac.
  2. Remove the battery.
  3. Press the power button and hold it for a few seconds.
  4. Reinstall the battery.
  5. Press the power button to turn on your Mac.

If the battery is non-removable:

  1. Shut down your Mac.
  2. Press Shift+Control+Option on your keyboard and press the power button at the same time.
  3. Hold these keys for 10 seconds.
  4. Release the keys.
  5. Press the power button again to turn on your Mac.

Other than the above, make sure all your cables are connected and fully seated, make sure all the screws are in their correct holes, so you do not cause damage by putting a long screw in a small hole :(

Hope this helps :)

Bu yanıt yardımcı oldu mu?

Puan 0

2 Yorum:

Thank you very much. The battery is removable. I tried both reset but no Change.

tarafından

I would then follow @danj advice as it would be the next logical step.

tarafından

Yorum Ekle

@nobert - Yep, you over did the paste! You'll need to clean it all off. sadly its going to take a bit more than wiping off as you’ve got it over the small SMD devices that are also on the green chip carrier. Using a soft tooth brush and 90% isopropyl alcohol carefully clean off the caught paste around the SMD components. Use extreme care as you don’t want to lift any of them off which is quite easy!

Clean the heat sink as well asd then use one quarter of what you used! It’s not the quantity it’s the placement and not over doing it thats important only getting it on the Black silicon chip.

Bu yanıt yardımcı oldu mu?