This guide will show the procedure for removing each segment of the pump rod. It can be used to replace the entire rod, or just to replace a single pump rod segment.

Aletler

Hiçbir alete gerek yok.

Parçalar

Hiçbir parçaya gerek yok.

Assemble the required tools, including the Afridev tool and crescent wrenches.
  • Assemble the required tools, including the Afridev tool and crescent wrenches.

Yorum Ekle

Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.
  • Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.

Yorum Ekle

  • Loosen the bolt on front of the face plate with the Afridev tool.

  • Remove the plate from the pump by lifting it straight up.

Yorum Ekle

  • Insert the T-handle into the top cylinder of the exposed pump rod.

Yorum Ekle

  • Loosen the 2 bolts on either side of handle.

  • It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.

Yorum Ekle

  • Loosen the 2 bolts on either side of the head to remove the handle from the pump rod.

  • It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.

Yorum Ekle

  • Lift the handle to a horizontal position.

Yorum Ekle

  • While one person lifts up on the T-handle, remove the bolt and connection pieces.

Yorum Ekle

  • Remove the bolt and connection pieces from the handle.

  • Set the bolt pieces in a sanitary place, such as a bucket, to prevent contamination.

Yorum Ekle

  • Remove the handle from the pump.

  • Be sure to set the handle in a sanitary place to prevent contamination.

Yorum Ekle

  • Grab firmly on the T-handle and lift the pump rod straight up.

  • Expose the first connection of the pump rod, and support the portion below the connection.

Yorum Ekle

  • While holding the pump rod below the first connection tightly, lower the first portion of the rod to a horizontal position.

Yorum Ekle

  • Unhook the first connection by pushing it out and down, then pulling it away from the rest of the rod.

Yorum Ekle

  • Repeat steps 11-13 for the remaining sections of pump rod.

  • Be sure to set the pump rod segments above the ground to avoid contamination.

Yorum Ekle

Sonuç

To reassemble your device, follow these instructions in reverse order.