Ana içeriğe geç

Bionaire BAP 600 Control Board Replacement

Neye ihtiyacın var

  1. Bionaire BAP 600 Control Board Replacement, Base/Intake: adım 1, 1 resimden 1.
    • Rotate base counterclockwise, supporting top with opposite hand.

  2. Bionaire BAP 600 Control Board Replacement: adım 2, 1 resimden 1.
    • Pull base away from housing exposing air filter.

  3. Bionaire BAP 600 Control Board Replacement, Air Filter: adım 3, 1 resimden 1.
    • Grab the edge of the filter housing and pull the filter away from the rest of the device.

  4. Bionaire BAP 600 Control Board Replacement: adım 4, 1 resimden 1.
    • Gently pull apart each fold of the filter to check for abrasions or other anomalies. Clean with a dust rag if necessary.

  5. Bionaire BAP 600 Control Board Replacement, Outer Shell: adım 5, 1 resimden 1.
    • Remove all 6 screws from the LED housing.

  6. Bionaire BAP 600 Control Board Replacement: adım 6, 1 resimden 1.
    • After the 6 screws are removed, remove the LED housing from the bottom of the device by lifting it off.

  7. Bionaire BAP 600 Control Board Replacement: adım 7, 1 resimden 1.
    • Using two fingers lift the translucent LED cover from the inside. Repeat this step for the second tab.

  8. Bionaire BAP 600 Control Board Replacement: adım 8, 1 resimden 1.
    • After lifting 45 degrees, pull the translucent tab away from thee housing. Repeat this step for the second LED cover.

  9. Bionaire BAP 600 Control Board Replacement: adım 9, 1 resimden 1.
    • Locate the tab about 1 inch below the top vent. Insert a flat tool laterally past the tab and press in toward the center of the device. As the tab is being held down, pull the two halves of the egg apart to keep the shell open.

  10. Bionaire BAP 600 Control Board Replacement: adım 10, 1 resimden 1.
    • Locate the second tab on the back of the device approximately 2 inches above the power cord.

    • Insert the flat tool at a slight angle toward the left of the power cord. Depress the tab and pull the two halves of the shell apart.

  11. Bionaire BAP 600 Control Board Replacement: adım 11, 1 resimden 1.
    • Locate the bottom tab on the front side at the same height as the bottom tab on the back side.

    • Depress the tab using a flat tool at a slight angle and pull the halves apart.

  12. Bionaire BAP 600 Control Board Replacement: adım 12, 1 resimden 1.
    • Locate the last tab about one inch below the top on the front side.

    • Depress the tab using the flat tool at a slight angle and finish pulling the removable half of the shell off.

  13. Bionaire BAP 600 Control Board Replacement: adım 13, 1 resimden 1.
    • Locate the screw housing opposite of the control board, and remove the screw.

  14. Bionaire BAP 600 Control Board Replacement: adım 14, 1 resimden 1.
    • Locate the control board and grab it by the top and bottom firmly. Pull the board straight out being careful not to flex the circuit while removing.

  15. Bionaire BAP 600 Control Board Replacement: adım 15, 1 resimden 1.
    • Locate the screw that was being hidden by the control board and remove it to release the second half of the shell.

  16. Bionaire BAP 600 Control Board Replacement: adım 16, 1 resimden 1.
    • Remove the released half of the shell to finish removing the entire outer shell of the device.

  17. Bionaire BAP 600 Control Board Replacement, Control Board: adım 17, 1 resimden 1.
    • Unplug 7 pin connector

  18. Bionaire BAP 600 Control Board Replacement: adım 18, 1 resimden 1.
    • Unplug 2 pin wires which connects the front LED's.

  19. Bionaire BAP 600 Control Board Replacement: adım 19, 2 resimden 1. Bionaire BAP 600 Control Board Replacement: adım 19, 2 resimden 2.
    • Remove two screws

  20. Bionaire BAP 600 Control Board Replacement: adım 20, 1 resimden 1.
    • Unplug pins

    • Use scissors to cut zip ties

  21. Bionaire BAP 600 Control Board Replacement: adım 21, 3 resimden 1. Bionaire BAP 600 Control Board Replacement: adım 21, 3 resimden 2. Bionaire BAP 600 Control Board Replacement: adım 21, 3 resimden 3.
    • Unplug rest of pin connections

    • Remove Neutral and Hot wires

    • They are the two black wires

    • Pull them out

  22. Bionaire BAP 600 Control Board Replacement: adım 22, 3 resimden 1. Bionaire BAP 600 Control Board Replacement: adım 22, 3 resimden 2. Bionaire BAP 600 Control Board Replacement: adım 22, 3 resimden 3.
    • Unscrew two screws

    • Inspect capacitor for any bulges ( if it has a bulge , it means it is need to be replaced)

    • Check for burnt solder in the back of circuit board

Sonuç

To reassemble your device, follow these instructions in reverse order.

2 farklı kişi bu kılavuzu tamamladı.

Alexander Tarancon

Üyelik tarihi: 10/12/16

49 İtibar

2 adet Kılavuz yazıldı

Ekip

IUPUI, Team 4-4, Baechle Fall 2016 IUPUI, Team 4-4, Baechle Fall 2016 üyesi

IUPUI-BAECHLE-F16S4G4

5 Üyeler

7 adet Kılavuz yazıldı

Bir Yorum

I knew there were tabs because I could see one but I didn’t know where the others were so I just waited, found your guide, and studied it carefully. Thanks Alexander!

Randall MacDonald - Yanıt

Yorum Ekle

İstatistikleri Görüntüle:

Son 24 Saat: 0

Son 7 gün: 1

Son 30 gün: 5

Her zaman: 506