Ana içeriğe geç

Direct-Drive Turntable Cartridge and Needle Replacement

Neye ihtiyacın var

  1. Direct-Drive Turntable Cartridge and Needle Replacement, Cartridge and Needle: adım 1, 1 resimden 1.
    • Check the needle and cartridge to see if they need to be replaced.

    • If the cartridge is touching your vinyl, it must be replaced.

    • Additionally, if you can hear scraping when playing the record, or if you see new scratch marks on the vinyl, it is time to change the cartridge and needle.

  2. Direct-Drive Turntable Cartridge and Needle Replacement: adım 2, 3 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 2, 3 resimden 2. Direct-Drive Turntable Cartridge and Needle Replacement: adım 2, 3 resimden 3.
    • Manually unscrew the bulb on the tone arm from the headshell.

    • Pull out the headshell once it is completely unscrewed from the tone arm.

  3. Direct-Drive Turntable Cartridge and Needle Replacement: adım 3, 3 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 3, 3 resimden 2. Direct-Drive Turntable Cartridge and Needle Replacement: adım 3, 3 resimden 3.
    Bu adımda kullanılan alet:
    Flathead 3/32" or 2.5 mm Screwdriver
    $5.49
    • Use a 2.5 mm flathead screwdriver to remove both screws from the headshell.

  4. Direct-Drive Turntable Cartridge and Needle Replacement: adım 4, 2 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 4, 2 resimden 2.
    • Gently pull the four wires out from the back of the cartridge.

  5. Direct-Drive Turntable Cartridge and Needle Replacement: adım 5, 2 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 5, 2 resimden 2.
    • Pull the needle off of the new cartridge to ensure it does not get damaged during installation.

  6. Direct-Drive Turntable Cartridge and Needle Replacement: adım 6, 3 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 6, 3 resimden 2. Direct-Drive Turntable Cartridge and Needle Replacement: adım 6, 3 resimden 3.
    • Connect the wires on the headshell to the new cartridge by matching the colors of the wires to the pins on the cartridge.

    • Place the headshell back onto the cartridge, being sure to line up the holes for the screws.

    • Place the screws back into the holes connecting the headshell and the new cartridge.

  7. Direct-Drive Turntable Cartridge and Needle Replacement: adım 7, 3 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 7, 3 resimden 2. Direct-Drive Turntable Cartridge and Needle Replacement: adım 7, 3 resimden 3.
    • Screw the screws in using a 2.5 mm flathead screwdriver. Ensure the headshell is securely attached to the cartridge.

    • Slide the new needle back onto the cartridge.

  8. Direct-Drive Turntable Cartridge and Needle Replacement: adım 8, 3 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement: adım 8, 3 resimden 2. Direct-Drive Turntable Cartridge and Needle Replacement: adım 8, 3 resimden 3.
    • Attach the headshell to the tone arm and screw the headshell in from the tip of the tone arm.

    • Ensure that the headshell is secured in the tone arm and that there is no movement in the headshell when connected to the tone arm.

  9. Direct-Drive Turntable Cartridge and Needle Replacement: adım 9, 1 resimden 1.
    • Place the needle onto a vinyl record and ensure that only the tip of the needle is touching the record and not the cartridge.

  10. Direct-Drive Turntable Cartridge and Needle Replacement, Check alignment of the needle: adım 10, 3 resimden 1. Direct-Drive Turntable Cartridge and Needle Replacement, Check alignment of the needle: adım 10, 3 resimden 2. Direct-Drive Turntable Cartridge and Needle Replacement, Check alignment of the needle: adım 10, 3 resimden 3.
    • For good sound the needle has to fit parallel into the record groove. Othrewise the sound isn't leveled between left and right channel.

    • Therefore templates are available to buy or to print. They got orthogonal lines on the area where the needle is setting in and where it is setting off.

    • The needle should be parallel to the lines on the template at R120,9 mm. If not, the screws shown in step 3 can be loosened and the cartridge can be adjusted. After adjusting tight the screws up again.

Bitiş Çizgisi

2 farklı kişi bu kılavuzu tamamladı.

0 Yorum

Yorum Ekle

İstatistikleri Görüntüle:

Son 24 Saat: 2

Son 7 gün: 6

Son 30 gün: 18

Her zaman: 1,078