Giriş

The scanner motor powers the physical movement of the scanning mechanism. This mechanism moves across an entire document, copying its contents, so that the printer can scan, fax, and/or print a copy of the original document. This motor may stop working due to a broken fuse or faulty connection and ultimately may need to be replaced.

  1. Check that the printer is unplugged to prevent shock.
    • Check that the printer is unplugged to prevent shock.

    • Turn the printer so the front buttons are facing away from you.

    Yorum Ekle

  2. Locate the 3mm Phillips #0 screw in the top left corner of the printer.
    • Locate the 3mm Phillips #0 screw in the top left corner of the printer.

    • Remove the screw using a Phillips head screwdriver.

    • Store the screw in a safe place where you can access them later.

    Yorum Ekle

    • Flip the top of the printer up so that you can see the inside of the printer.

    • There is a white ribbon cable in the right top corner of the printer.

    • Make sure that the white ribbon does not come detached from the right side of the printer.

    Yorum Ekle

    • Lay the scanner face up so you can access the under side, and place something, such as a piece of Styrofoam, underneath of it so that the white tape does not become detached.

    • Locate the four 3mm Phillips #2 screws along the edge, and remove all of them.

    • Store the screws in a safe place where you can access them later.

    Yorum Ekle

    • Locate the seam on between outer shell of the printer and the inside of the printer.

    • Starting from the top of the printer, use the plastic opening tool to slowly pry the scanner apart along the seam.

    Yorum Ekle

    • Detach the bottom of the scanner.

    • Flip the bottom of the scanner over so that it rests on top of the printer.

    • This gives you access to the motor.

    Yorum Ekle

    • Gently lift the scanner bar in order to remove it from the scanner.

    • Detach the white ribbon cable from the scanner bar.

    Yorum Ekle

    • Remove the two 3mm Phillips #2 screws on the underside of the scanner bar attached to the silver motor.

    • Remove the motor from the scanner bar by gently pulling the motor upwards.

    Yorum Ekle

Sonuç

To reassemble your device, follow these instructions in reverse order.

Kimberly Pugel

Üyelik tarihi: 07-04-2014

389 İtibar

3 adet Kılavuz yazıldı

Takım

Cal Poly, Team 6-1, Forte Spring 2014 Cal Poly, Team 6-1, Forte Spring 2014 üyesi

CPSU-FORTE-S14S6G1

4 Üyeler

5 adet Kılavuz yazıldı

0 Yorum

Yorum Ekle

İstatistikleri Görüntüle:

Son 24 Saat: 0

Son 7 Gün: 1

Son 30 Gün: 2

Her zaman: 524