Eureka 1660SP External Start Switch Realignment

Neye ihtiyacın var

  1. Eureka 1660SP External Start Switch Realignment, Motor Housing: adım 1, 2 resimden 1. Eureka 1660SP External Start Switch Realignment, Motor Housing: adım 1, 2 resimden 2.
    • Before you start, make sure your vacuum is unplugged the power outlet.

    • Press and hold down the black button below the handle while pulling the pole out.

  2. Eureka 1660SP External Start Switch Realignment: adım 2, 2 resimden 1. Eureka 1660SP External Start Switch Realignment: adım 2, 2 resimden 2.
    • Press the black separator switch to separate the top and bottom halves of the vacuum.

  3. Eureka 1660SP External Start Switch Realignment: adım 3, 3 resimden 1. Eureka 1660SP External Start Switch Realignment: adım 3, 3 resimden 2. Eureka 1660SP External Start Switch Realignment: adım 3, 3 resimden 3.
    • Use a #2 Phillips head screwdriver to remove six 13.9mm screws from the side of the motor housing (top half) as shown.

    • Remove two 14.1mm screws from the front face of the housing. You are now all set to open the housing.

    • Keep a watchful eye on the two screws from the front face. These two have additional collars to their necks and will not fit in any of the other holes, yet no other screw will fit in their spots without the collar.

  4. Eureka 1660SP External Start Switch Realignment, Realignment of plastic start switch piece: adım 4, 3 resimden 1. Eureka 1660SP External Start Switch Realignment, Realignment of plastic start switch piece: adım 4, 3 resimden 2. Eureka 1660SP External Start Switch Realignment, Realignment of plastic start switch piece: adım 4, 3 resimden 3.
    • If the external switch is slightly misaligned as shown, realign it with the internal switch.

    • Make sure the spring loaded button on the underside of the housing is intact when reassembling the motor housing. It is prone to eject when opening the motor housing.

Sonuç

To reassemble your device, follow these instructions in reverse order.

Evan Fodi

Üyelik tarihi: 09/24/13

122 İtibar

2 adet Kılavuz yazıldı

Ekip

UMass Dartmouth, Team 1-1, Gulbrandsen Fall 2013 UMass Dartmouth, Team 1-1, Gulbrandsen Fall 2013 üyesi

UMASSD-GULBRANDSEN-F13S1G1

3 Üyeler

12 adet Kılavuz yazıldı

0 Yorum

Yorum Ekle

İstatistikleri Görüntüle:

Son 24 Saat: 0

Son 7 gün: 2

Son 30 gün: 5

Her zaman: 2,446