Giriş

If the battery on your Fluke 77 Series III Multimeter needs to be replaced, this guide details the steps for doing so. Replacing the battery is a routine, but critical part replacement for the Fluke 77 Series III Multimeter.

  1. Be sure any test leads are out and the multimeter is off before opening the device.
    • Be sure any test leads are out and the multimeter is off before opening the device.

    • Turn the multimeter so it is display side down.

    • Lift up the back stand of the device by putting your thumb in the curved well at the bottom of the device, so you have access to the two covered screws below.

    Yorum Ekle

  2. Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.
    • Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.

    Yorum Ekle

  3. Spread Fixmas Cheer
    Get $12 off your purchase of $50 or more with code FIXMAS12
    Spread Fixmas Cheer
    Get $12 off your purchase of $50 or more with code FIXMAS12
    • Turn the Fluke 77 Series III Multimeter back over so that it is display side up.

    • Pry the front panel from the back panel at the seam.

    • If the front panel does not come off easily, move a plastic opening tool along the seam until the panels separate completely.

    Yorum Ekle

    • When doing this next step, make sure to remove the battery slowly, so you don't damage the wires connecting the battery to the device.

    • Locate the 9V battery in the lower right corner of the device.

    • Pull the battery out of its terminal.

    Yorum Ekle

    • Only pull on the metal snaps and battery. Pulling the cords may damage them.

    • Detach the two metal snaps from the battery.

    Yorum Ekle

Sonuç

To reassemble your device, follow these instructions in reverse order.

4 başka kişi bu kılavuzu tamamladı.

Jessica Bombardier Shaw

Üyelik tarihi: 29-01-2014

961 İtibar

7 adet Kılavuz yazıldı

Takım

Cal Poly, Team 2-10, Amido Winter 2014 Cal Poly, Team 2-10, Amido Winter 2014 üyesi

CPSU-AMIDO-W14S2G10

4 Üyeler

10 adet Kılavuz yazıldı

Bir Yorum

Easy to understand and all went well!

petruskewichw - Yanıt

Yorum Ekle

İstatistikleri Görüntüle:

Son 24 Saat: 4

Son 7 Gün: 32

Son 30 Gün: 159

Her zaman: 6,866