Ana içeriğe geç
Onarım Topluluğuna Katılın - Hesap Oluşturun

Microtek ScanMaker 5900 Stepper Motor Replacement

Neye ihtiyacın var

  1. Microtek ScanMaker 5900 Stepper Motor Replacement, Remove serial port connection: adım 1, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement, Remove serial port connection: adım 1, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement, Remove serial port connection: adım 1, 3 resimden 3.
    • Loosen the screws on the serial port by turning them counter clockwise by hand.

    • After loosening the screws, pull the serial port out.

    FixBot'a Sor

    Yorum Ekle

  2. Microtek ScanMaker 5900 Stepper Motor Replacement, Remove Lid: adım 2, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement, Remove Lid: adım 2, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement, Remove Lid: adım 2, 3 resimden 3.
    • Lift lid to its vertical position.

    • Pull lid straight up to remove it from the scanner.

    FixBot'a Sor

    Yorum Ekle

  3. Microtek ScanMaker 5900 Stepper Motor Replacement, Detach plastic latches: adım 3, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement, Detach plastic latches: adım 3, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement, Detach plastic latches: adım 3, 3 resimden 3.
    • Push the plastic opening tools into the crack between the top and the bottom of the chassis.

    FixBot'a Sor

    Yorum Ekle

  4. Microtek ScanMaker 5900 Stepper Motor Replacement, Continue latch detachment: adım 4, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement, Continue latch detachment: adım 4, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement, Continue latch detachment: adım 4, 3 resimden 3.
    • After placing one plastic opening tool into the slit, slide other plastic opening tools along the slit to detach the top from the bottom of the chassis.

    • Go all the way along the chassis until you can lift the upper lid.

    FixBot'a Sor

    Yorum Ekle

  5. Microtek ScanMaker 5900 Stepper Motor Replacement, Fully remove the upper lid: adım 5, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement, Fully remove the upper lid: adım 5, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement, Fully remove the upper lid: adım 5, 3 resimden 3.
    • Do not fully remove the lid until you remove the ribbon cable attached to the front of the upper lid.

    • Do this by grabbing the upper lid from the sides and rotating it ninety degrees so it is perpendicular to the bottom lid.

    • Grab the ribbon cable and gently pull it out of its slot with your fingers.

    • The upper lid can now safely be removed from the bottom lid.

    FixBot'a Sor

    Yorum Ekle

  6. Microtek ScanMaker 5900 Stepper Motor Replacement, Stepper Motor: adım 6, 2 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement, Stepper Motor: adım 6, 2 resimden 2.
    • Locate the stepper motor. With the front of the scanner facing you, the motor is located at the top left.

    • Disconnect the white connector from the vertical standing circuit board.

    FixBot'a Sor

    Yorum Ekle

  7. Microtek ScanMaker 5900 Stepper Motor Replacement: adım 7, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement: adım 7, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement: adım 7, 3 resimden 3.
    • Using a #2 Philips Screwdriver, unscrew the two 7.7mm screws holding the stepper motor in place.

    • The stepper motor will become loose, but not completely free.

    FixBot'a Sor

    Yorum Ekle

  8. Microtek ScanMaker 5900 Stepper Motor Replacement: adım 8, 3 resimden 1. Microtek ScanMaker 5900 Stepper Motor Replacement: adım 8, 3 resimden 2. Microtek ScanMaker 5900 Stepper Motor Replacement: adım 8, 3 resimden 3.
    Bu adımda kullanılan alet:
    Tweezers
    $4.99
    • Using tweezers gently remove the tread from the black gear on the stepper motor.

    • The stepper motor will become completely free.

    FixBot'a Sor

    Yorum Ekle

Sonuç

To reassemble your device, follow these instructions in reverse order.

İptal et: Bu kılavuzu tamamlamadım.

Bir başkası bu kılavuzu tamamladı.

Steven Shaginyan

Üyelik tarihi: 10/12/11

39 İtibar

4 adet Kılavuz yazıldı

Ekip

Cal Poly, Team 6-9, Regan Fall 2011 Cal Poly, Team 6-9, Regan Fall 2011 üyesi

CPSU-REGAN-F11S6G9

2 Üyeler

22 adet Kılavuz yazıldı

0Kılavuz Yorumları

Yorum Ekle

İstatistikleri Görüntüle:

Son 24 Saat: 0

Son 7 gün: 10

Son 30 gün: 52

Her zaman: 2,072