Follow these steps to disassemble the plastic casing of the RIDGID R84015 X2 power drill.

Using a Torx T20 screwdriver, remove the four screws attaching the back plate.
  • Using a Torx T20 screwdriver, remove the four screws attaching the back plate.

Yorum Ekle

Remove the five screws attaching the drill handle.
  • Remove the five screws attaching the drill handle.

Yorum Ekle

  • Remove the 4 screws attaching the front of the casing.

Yorum Ekle

  • With your drill taken apart, move your attention to the trigger and forward reverse switch.

Yorum Ekle

  • Check to see that the forward reverse switch isn't broken.

  • NOTE: small tab on trigger fits into groove on forward reverse switch

Yorum Ekle

  • With the battery attached, check that the wires work when the trigger is pulled.

  • Put multimeter wires here.

  • If wires work and drill doesn't, the problem is with the motor.

Yorum Ekle

  • Make sure plastic is not broken and switch is not stuck.

Yorum Ekle

  • Looks good, doesn't it?

Yorum Ekle

Bitiş Çizgisi

2 başka kişi bu kılavuzu tamamladı.

Brian

Üyelik tarihi: 12-04-2010

97 İtibar

1 Kılavuz yazıldı

Takım

Cal Poly, Team 15-48, Garner Spring 2010 Cal Poly, Team 15-48, Garner Spring 2010 üyesi

CPSU-GARNER-S10S15G48

6 Üyeler

5 adet Kılavuz yazıldı

Bir Yorum

I was able to diagnose and fix my problem with my black and decker following your instructions. TY