- | [* black] There will be two FPC cables. |
---|
- | [* black] One is wide in yellow color, which is screen cable. One is narrow in blue color, which is connected to control switch panel. |
---|
- | [* black] You can only release the blue one. Unlike the screen cable, the control switch panel connecter is so loose connected without any lock. So, the reason of this issue is loosen in the daily use. |
---|
- | [* black] Before you reinsert the cable, I recommended you clean the golden finger (actually black color). |
---|
+ | [* black] There will be two flexible printed circuit (FPC) cables. |
---|
+ | [* black] One of the FPC cables is wide and yellow in color, which corresponds to the screen cable. The other FPC cable is narrow and blue in color, which is connected to the control switch panel. |
---|
+ | [* black] You can only disconnect the narrow blue FPC cable. Unlike the screen cable, the connector for the control switch panel is loosely connected without any locking mechanism. Therefore, the issue is likely caused by frequent use, which has resulted in a loose connection over time. |
---|
+ | [* black] Before reinserting the cable, I recommend cleaning the golden contacts (which are actually black in color). |
---|