+[* icon_caution] Use caution while handling ribbon cables and ribbon cables connects to avoid damaging them.
+[* red] Locate these three ribbon cables located on the left side of the main PCB board.
+ [* black] Disconnect the ribbon cables.
+ [* icon_note] Two of these ribbon cables features a hole in them which can assist with disconnecting them. Use either a pair of tweezers or another tool with a thin point to pull out the ribbon cables utilizing this hole.
+[* black] Use a plastic spudger tool to carefully push up and disconnect the imaging sensor ribbon cable.