Step 4
Remove the single 2.3 mm Phillips screw securing the battery connector to the logic board. To reduce the risk of a short, you can use a battery isolation pick to disconnect the battery. Slide a battery isolation pick underneath the battery connector area of the logic board, and leave it in place while you work.
  • Remove the single 2.3 mm Phillips screw securing the battery connector to the logic board.

  • To reduce the risk of a short, you can use a battery isolation pick to disconnect the battery.

  • Slide a battery isolation pick underneath the battery connector area of the logic board, and leave it in place while you work.

ロジックボードに留められたバッテリーコネクターから2.3 mmプラスネジを1本、取り外します。

ショートの危険を減らすため、バッテリーを切り離すバッテリー分離ピックを使います。

バッテリー分離ピックをロジックボードのバッテリーコネクターの下に差し込み、作業中はそのままにしておいてください。