Hi, I would like to know if there is a guide to explain how to disassemble the Epson v600 in order to replace a broken lid...
Devamını okuCevaplar
Here are the steps necessary to replace a broken v600 scanner hinge: 1. Release the scanner lid from the base. The lid is attached to the base via the hinges. So in order to separate the lid and the base, you have to release the two hinges. This is easy to do, but just not readily apparent when you examine the scanner. If you have a replacement hinge, take a look at it and you will see a barbed area near the bottom. That part of the hinge is inserted into the base of the scanner. The barbed portion is oriented toward the rear of the scanner. So if you take a very small flat screwdriver and insert it in the opening in the base (just behind the hinge and push the bottom of the hinge pin slight forward while raising up the lid, the pin will pop right out of the base. Do this to both hinges and the top of the scanner will separate from the base (remaining connected only via the cable that runs between the two). 2. Disassemble the lid. - remove the screw that fastens the plate near where the cable enters the...
Devamını okuHere are the steps necessary to replace a broken v600 scanner hinge: 1. Release the scanner lid from the base. The lid is attached to the base via the hinges. So in order to separate the lid and the base, you have to release the two hinges. This is easy to do, but just not readily apparent when you examine the scanner. If you have a replacement hinge, take a look at it and you will see a barbed (slightly hooked) area near the bottom of the hinge pin. That part of the hinge is inserted into the base of the scanner. The barbed portion is oriented toward the rear of the scanner. So if you take a very small flat screwdriver and insert it in the opening in the base (just behind the hinge and push the bottom of the hinge pin slightly forward while raising up the lid, the pin will pop right up out of the base. Do this to both hinges and the top of the scanner will separate from the base (remaining connected only via the cable that runs between the two). 2. Disassemble the lid. (1) turn the lid over so the glass...
Devamını okuHere are the steps necessary to replace a broken v600 scanner hinge: 1. Release the scanner lid from the base. The lid is attached to the base via the hinges. So in order to separate the lid and the base, you have to release the two hinges. This is easy to do, but just not readily apparent when you examine the scanner. If you have a replacement hinge, take a look at it and you will see a barbed (slightly hooked) area near the bottom of the hinge pin. That part of the hinge is inserted into the base of the scanner. The barbed portion is oriented toward the rear of the scanner. So if you take a very small flat screwdriver and insert it in the opening in the base (just behind the hinge and push the bottom of the hinge pin slightly forward while raising up the lid, the pin will pop right up out of the base. Do this to both hinges and the top of the scanner will separate from the base (remaining connected only via the cable that runs between the two). 2. Disassemble the lid. (1) turn the lid over so the glass...
Devamını okuHere are the steps necessary to replace a broken v600 scanner hinge: 1. Release the scanner lid from the base. The lid is attached to the base via the hinges. So in order to separate the lid and the base, you have to release the two hinges. This is easy to do, but just not readily apparent when you examine the scanner. If you have a replacement hinge, take a look at it and you will see a barbed (slightly hooked) area near the bottom of the hinge pin. That part of the hinge is inserted into the base of the scanner. The barbed portion is oriented toward the rear of the scanner. So if you take a very small flat screwdriver and insert it in the opening in the base (just behind the hinge and push the bottom of the hinge pin slightly forward while raising up the lid, the pin will pop right up out of the base. Do this to both hinges and the top of the scanner will separate from the base (remaining connected only via the cable that runs between the two). 2. Disassemble the lid. (1) turn the lid over so the glass...
Devamını okuKılavuz Yorumları
Because it makes replacing the motherboard more difficult. For a few cents more, they could have placed a small connector inline between the fan and motherboard, making disconnecting the fan and top case really easy.