CSI signature series (1) control valve troubleshooting

Hi we have error code 3 which is an issue with the control valve? I think I need to take the cover off and check for debris? The manual is very vague and unhelpful.

Yanıtlandı! Cevabı görüntüle Ben de bu sorunu yaşıyorum

Bu iyi bir soru mu?

Puan 0
Yorum Ekle

1 Cevap

Filtre ölçütü:
Seçilen Çözüm

@shellyhyatt take a look at this CSI Signature Series SM and see if that pertains to your valve as well. Error 3 - Encoder is not sending a signal (Valve requires service to continue)

Yes, I would definitely consider opening it up and to take a look at it. See what you find. You could be looking at debris as well as corrosion etc.


Bu yanıt yardımcı oldu mu?

Puan 0

1 Yorum:

Yup! Ty - I have the paper manual and all it has it that code explanation and the exploded diagrams. I will try to find the screws and see what I can do/see:)

tarafından

Yorum Ekle